compute_utility_kiosk_base

Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Foundation + kiosk hardware composite for utility cabinets — LV electricity feeder pillars (DNO-suppli...

SERVERCivilquants SOURCEhttps://api.civilquants.com/mcp
High RISK CLASS
Category Execute
Parameters 41 required
Recommended Rate-limitedsee the rule below
Registry record Grade F, identity unverified Pull the record →

This record as markdown: /tools/com-civilquants-civilquants/compute-utility-kiosk-base.md

What compute_utility_kiosk_base does on Civilquants

AI agents invoke compute_utility_kiosk_base to trigger actions in Civilquants. What it does depends on the arguments the agent supplies, and its effects often reach beyond the immediate call: builds kicked off, notifications sent, workflows started.

ParameterTypeRequiredDescription
params object Yes Parameters for a utility kiosk base. Fields marked "(None → catalogue)" resolve from the catalogue entry at ``__post_init__`` time; an explicit non-None value
standard string
output_mode string
deliverables object

Parameters from the server's own tool schema.

Why compute_utility_kiosk_base is rated High

This tool triggers a parametric estimating engine that runs composite calculations delegating to sub-tools (pad_foundation), producing Bills of Quantities outputs. It is not a simple data read/query but an active computation that executes estimation logic across multiple assemblies. No data is permanently written or destroyed, and no financial transaction is made — it is a compute/execute operation.

From the tool's definition 'Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT' and 'Light-wrapper delegation around pad_foundation for the substructure (excavation, RC pad with pedestal, reinforcement), plus kiosk-specific PC-supply…

Risk signalsHigh parameter count (24 properties)

Questions about compute_utility_kiosk_base

What does the compute_utility_kiosk_base tool do? +

Paid tier only. Calling this without an authenticated CivilQuants account returns TIER_INSUFFICIENT — sign up at https://civilquants.com/pricing or use the free-tier alternative compute_manhole. Foundation + kiosk hardware composite for utility cabinets — LV electricity feeder pillars (DNO-supplied), Openreach FTTC cabinets (PIA-supplied), EV rapid-charging plinths, packaged DNO substations, and generic precast plinths. Light-wrapper delegation around pad_foundation for the substructure (excavation, RC pad with pedestal, reinforcement), plus kiosk-specific PC-supply hardware (1 complete unit on UPS route, 4 components — body / door / lock / base-plate — on Employer-PC route). Catalogue-driven supply-route defaults encode that LV pillars and FTTC cabinets are normally utility-provider-supplied complete units, while EV chargers, DNO substations, and generic plinths are normally Employer-PC-nominated per component. Example params: quantity=1 Nr (1–100), blinding_thickness_m=0.075 m (0.05–0.15), working_space_m=0.3 m (0–1). Example call: {"params": {"quantity": 1, "blinding_thickness_m": 0.075, "working_space_m": 0.3}, "standard": "MMHW"}. Omitted parameters use sensible engineering defaults. Pass deliverables=["xlsx","dxf","pdf"] (any subset) to also receive one-shot download URLs in the same call: Excel BoQ (both tiers, watermarked free) plus the dimensioned DXF (CAD) and PDF drawing sheets (paid tier). It is categorised as a Execute tool in the Civilquants MCP Server, which means it can trigger actions or run processes. Use rate limits and argument validation.

What parameters does compute_utility_kiosk_base accept? +

compute_utility_kiosk_base accepts 4 parameters: params, standard, output_mode, deliverables. Required: params. The full parameter table on this page comes from the server's own tool schema.

How do I enforce a policy on compute_utility_kiosk_base? +

Register the Civilquants MCP server in PolicyLayer and add a rule for compute_utility_kiosk_base: allow, deny, rate-limit, or require approval. Point your MCP client at the PolicyLayer proxy URL and the rule is enforced on every call, before it reaches Civilquants. Nothing to install.

What risk level is compute_utility_kiosk_base? +

compute_utility_kiosk_base is a Execute tool with high risk. Execute tools should be rate-limited and have argument validation enabled.

Can I rate-limit compute_utility_kiosk_base? +

Yes. Add a rate_limit block to the compute_utility_kiosk_base rule in your PolicyLayer policy. For example, setting max: 10 and window: 60 limits the tool to 10 calls per minute. Rate limits are tracked per agent session and reset automatically.

How do I block compute_utility_kiosk_base completely? +

Set action: deny in the PolicyLayer policy for compute_utility_kiosk_base. The AI agent will receive a policy violation error and cannot call the tool. You can also include a reason field to explain why the tool is blocked.

What MCP server provides compute_utility_kiosk_base? +

compute_utility_kiosk_base is provided by the Civilquants MCP server (https://api.civilquants.com/mcp). PolicyLayer sits as a proxy in front of this server to enforce policies before tool calls reach the server.

More on Civilquants, and thousands of servers like it.

// THE MCP REGISTRY

PolicyLayer tracks 44,603 MCP servers and 515,000+ tools.

Every server has a live record: who publishes it, whether it answers without auth, its risk grade, every tool classified, the recommended policy. This page is one line of Civilquants's. Pull the full record:

Teams ship this data inside their own products. See what a licence covers →

// GET IN TOUCH

Have a question or want to learn more? Send us a message.

Message sent.

We'll get back to you soon.